CKFBV - GUA-1017-1, SKYFLEX AIRCRAFT SEALANT

  • MSDS: CKFBV
  • Manufacturer: W L GORE AND ASSOCIATES INC
  • Product Name: GUA-1017-1, SKYFLEX AIRCRAFT SEALANT
  • National Stock Number: 8030-01-368-7208
Product Identification

Product ID:GUA-1017-1, SKYFLEX AIRCRAFT SEALANT
MSDS Date:08/18/1997
FSC:8030
NIIN:01-368-7208
Status Code:A
MSDS Number: CKFBV

Responsible Party
W. L. GORE & ASSOCIATES, INC.
1901 BARKSDALE ROAD
NEWARK, DE 19711
US

Emergency Phone: 302-368-3700/703-527-3887

Info Phone: 302-368-3700/ 703-527-3887

Preparer: THOMAS DYKES

Cage: 17217

Contractor
W. L. GORE & ASSOCIATES, INC.
NEWARK, DE 19711 US

Telephone: 302-368-3700/ 703-527-3887

Cage: 17217

Ingredients

POLYTETRAFLUOROETHYLENE

CAS: 9002-84-0

RTECS: KX4025000


INORGANIC PIGMENTS, (PROPRIETARY)

Hazards

Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:NO ACUTE OR CHRONIC HEALTH EFFECTS
ANTICIPATED UNDER NORMAL HANDLING AND USE. OVERHEATING
(OVER260C/500F), BURNING, GRINDING, MELTING, CUTTING, ANY PROCESS
RELEASING DUST, FUME, OR GAS MAY CAUSE IRRIT ATION OF EYES, SKIN,
RESPIRATORY TRACT, "POLYMER FUME FEVER" (A TEMPORARY FLU-LIKE
ILLNESS WITH FEVER, CHILLS, SOMETIMES COUGH, OF ABOUT 24 HOURS
DURATION). INHALATION OF LOW CONCENTRATIONS OF HYDROGE N FLUORIDE,
CARBONYL FLUORIDE , OTHER THERMAL DECOMPOSITION PRODUCTS MAY RESULT
IN TEMPORARY LUNG IRRITATION, DIFFICULTY BREATHING, SHORTNESS OF
BREATH. SMOKERS SHOULD AVOID CONTAMINATED TOBACCO PRODU CTS AND
WASH HANDS BEFORE SMOKING.
Explanation of Carcinogenicity:NO INGREDIENT IN THIS PRODUCT IS LISTED
BY IARC, NTP, OSHA, OR ACGIH AS A CARCINOGEN.
Effects of Overexposure:EXPOSURE TO THIS PRODUCT IN ITS PURCHASED FORN
IS NOT EXPECTED TO PRESENT A HEALTH HAZARD. THE HEALTH EFFECTS OF
THIS PRODUCT HAVE NOT BEEN EVALUATED. THE EFFECTS LISTED IN THE
"HEALTH HAZARD ACUTE AN D CHRONIC" FIELD ARE FOR THE INDIVIDUAL
COMPONENTS. SYMPTOMS FROM OVERHEATING, BURNING, GRINDING, MELTING,
CUTTING, OR ANY OTHER PROCESS CAUSING DUST, FUME, OR GAS:
IRRITATION OF THE EYES, SKIN, RESP IRATORY TRACT, FEVER, CHILLS,
COUGH, LUNG IRRITATION, DIFFICULTY BREATHING, SHORTNESS OF BREATH.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING
DISEASES OF THE LUNGS MAY HAVE INCREASED SUSCEPTIBILITY TO DUST OR
THERMAL DECOMPOSITION PRODUCTS.

First Aid

First Aid:INHALATION: IF INHALATION OF THERMAL DECOMPOSITION PRODUCTS
OR DUST PRODUCES RESPIRATORY DIFFICULTY, OR IRRITATION MOVE PERSON
TO FRESH AIR. CONSULT A PHYSICIAN IF SYMPTOMS PERSIST. IF
BREATHING STOP S, GIVE ARTIFICIAL RESPIRATION AND SEEK MEDICAL
ATTENTION. SKIN: IF MOLTEN MATERIAL GETS ON SKIN, COOL RAPIDLY WITH
COLD WATER. DO NOT ATTEMPT TO REMOVE FROM SKIN. OBTAIN MEDICAL
TREATMENT FOR THEM AL BURNS. EYES: FLUSH WITH LARGE AMOUNTS OF
WATER FOR AT LEAST 15 MINUTES, OCCASIONALLY LIFTING THE LOWER AND
UPPER LIDS.GET MEDICAL ATTENTION IF SYMPTOMS PERSIST. INGESTION:
GET MEDICAL ATTENTION.

Fire Fighting

Flash Point:NOT ESTABLISHED.
Lower Limits:N/E
Upper Limits:N/E
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER, OR REGULAR
FOAM. USE EXTINGUISHING MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:KEEP PERSONNEL REMOVED FROM AND UPWIND OF
FIRE. FULL EMERGENCY EQUIPMENT WITH SELF-CONTAINED BREATHING
APPARATUS AND FULL PROTECTIVE CLOTHING SHOULD BE WORN. HYDROGEN
FLUORIDE FUMES EMITTED DURING A FIRE CAN REACT WITH WATER TO FORM
HYDROFLUORIC ACID. WEAR NEOPRENE GLOVES WHEN HANDLING REFUSE FROM
FIRE.
Unusual Fire/Explosion Hazard:HAZARDOUS GASES/VAPORS PRODUCED IN FIRE
ARE HYDROGEN FLUORIDE (HF), CARBONYL FLUORIDE, CARBON MONOXIDE,
CARBON DIOXIDE, AND LOW MOLECULAR WEIGHT FLUOROCARBONS.

Accidental Release

Spill Release Procedures:USE APPROPRIATE PERSONAL PROTECTIVE EQUIPMENT
DURING CLEAN-UP. REVIEW FIRE FIGHTING MEASURES AND HANDLING
PROCEEDINGS BEFORE STARTING CLEAN-UP. SPILLED MATERIAL MAY PRESENT
A SLIPPING HAZARD. COLLECT BY SWEEPING OR VACUUMING ANY LOOSE
MATERIAL TO PREVENT ACCUMULATION OF PRODUCT.

Handling

Handling and Storage Precautions:AVOID BREATHING DUST OR DECOMPOSITION
PRODUCTS. AVOID CONTAMINATION OF CIGARETTES OR TOBACCO WITH DUST
FROM THIS MATERIAL. STORE IN A DRY AREA

Exposure Controls

Respiratory Protection:RESPIRATORY PROTECTION IS NOT NORMALLY REQUIRED
UNDER ANTICIPATED CONDITIONS OF USE. IF RESPIRATORS ARE NECESSARY,
USE ONLY NIOSH/MSHA APPROVED RESPIRATORS.
Ventilation:USE LOCAL EXHAUST VENTILATION WHEN HEATING OR MELTING
MATERIAL. PROVIDE EXHAUST VENTILATION IN ACCORDANCE WITH GUIDELINES
IN INDUSTRIAL VENTILATION BY ACGIH.
Protective Gloves:WEAR NEOPRENE GLOVES WHEN HANDLING REFUSE FROM FIRE.
Eye Protection:SAFETY GLASSES SHOULD BE WORN IF HANDLING PRESENTS A
HAZARD OF EYE INJURY.
Other Protective Equipment:PROTECTIVE CLOTHING: NONE REQUIRED UNLESS
NECESSARY FOR PROTECTION FROM THERMAL BURNS OR DUST PARTICLES.
Work Hygienic Practices:AVOID BREATHING DUST OR DECOMPOSITION PRODUCTS.
AVOID CONTAMINATION OF CIGARETTES OR TOBACCO WITH DUST FROM THIS
PRODUCT.
Supplemental Safety and Health

Chemical Properties

HCC:N1
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Spec Gravity:.4-1.7(VARIES WITH SIZE)
Solubility in Water:INSOLUBLE.
Appearance and Odor:WHITE OR GRAY COLORED, RIBBED OR NON-RIBBED,
MARSHMALLOWY TAPE. NO ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
MOLTEN ALKALI METALS, STRONG OXIDIZERS, STRONG ACIDS AND SOME REACTIVE
INTERHALOGEN COMPOUNDS.
Stability Condition to Avoid:STABLE AT NORMAL TEMPERATURES AND STORAGE
CONDITIONS. AVOID HEATING ABOVE 300C(572F). ABNORMALLY LONG
PROCESSING TIME OR HIGH TEMPERATURES CAN PRODUCE IRRITATION AND
TOXIC FUMES.
Hazardous Decomposition Products:HEATING ABOVE 572F EVOLVES PARTICLE
MATTER. TRACE AMOUNTS OF HYDROGEN FLUORIDE AND CARBONYL FLUORIDE
EVOLVED AT 750F. CARBON MONOXIDE, CARBON DIOXIDE EVOLVED WHEN
HEATED IN AIR AT 600F.

Disposal

Waste Disposal Methods:PREFERRED OPTIONS FOR DISPOSAL ARE 1) RECYCLING
AND 2) LANDFILL. INCINCRATE ONLY IF INCINCRATOR IS CAPABLE OF
SCRUBBING OUT HYDROGEN FLUORIDE AND OTHER ACIDIC COMBUSTION
PRODUCTS. TREATMENT, STORAGE, TRANSPORATION, AND DISPOSAL SHOULD
BE IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE/PROVINCIAL, AND L
OCAL REGULATIONS.

Toxicology

Toxicological Information:POLYTETRAFLUOROETHYLENE (PTFE): INHALATION
LC50 (RAT): > 4,900 MG/M3. AT VERY HIGH EXPOSURE LEVELS, ANIMALS
WERE SUFFOCATED BY ACCUMULATED DUST IN LUNGS. REPEATED EXPOSURE
LEVELS, ANIMALS WERE SUFFOCA TED BY ACCUMULATED DUST IN THE LUNGS.

Ecology

Ecological:NO INFORMATION AVAILABLE. RCRA STATUS: IF DISCHARGED IN ITS
PURCHASED FORM, THIS PRODUCT WOULD NOT BE A HAZARDOUS WASTE BY
LISTING. HOWEVER, UNDER RCRA, IT IS THE RESPONSIBILITY OF THE
PRODUCT USER AT THE TIME OF DISPOSAL, WHETHER A MATERIAL
CONTAINING THE PRODUCT OR DERIVED FROM THE PRODUCT SHOULD E
CLASSIFIED AS A HAZARDOUS WASTE, (40 CFR 261.20-24).

Transport

Transport Information:DOT, IMO, ICAO/IATA HAZARD CLASSIFICATION: NOT
REGULATED.

Regulatory

SARA Title III Information:SECTION 302 EXTREMELY HAZARDOUS SUBSTANCES:
NONE. SECTION311/312 HAZARD CATEGORIES: NON-HAZARDOUS UNDER SECTION
311/312. SECTION 313 TOXIC CHEMICALS: NONE.U
Federal Regulatory Information:US TSCA: THE INGREDIENTS OF THIS PRODUCT
ARE ALL ON THE TSCA INVENTORY LIST. EEC EINECS: INFORMATION IS NOT
AVAILABLE. CERCLA REPORTABLE QUANTITY: NONE.
State Regulatory Information:STATE REGULATIONS (U.S.), COMPONENT:
POLYTETRAFLUOROETHYLENE, CAS# 9002-84-0, WT%=90-100: MA, NJ, CA,:
NO; PA: YES. MA= MASSACHUSETTES SUBSTANCE LIST. NJ= NEW JERSEY
RIGHT TO KNOW HAZARDOUS SUBSTANCE LIST. CA= CALIFORNIA SAFE
DRINKING WATER AND TOXIC ENFORCEMENT ACT (PROPOSITION 65)
SUBSTANCES. CN= CANADIAN WORKPLACE HAZARDOUS MATERIALS INFORMATION
SYSTEM (WHMIS) INGREDIENT DISCLOSURE LIST. PA= PE NNSYLVANIA
HAZARDOUS SUBSTANCE LIST.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.